| Date: 7/5/2010 | Time: 08:00 AM | Report ID: sample |
| Property: 123 Dream Home Blvd Louisville KY 40241 |
Customer: Mr. Joe Smith |
Real Estate Professional: |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
Safety (S) = I visually observed a condition in the home that may pose a safety risk or hazardous condition. These conditions should be rectified before occupying the home.
NOTICE: This report is provided for the specific benefit of the client named above and is based on observations at the time of the inspection. If you did not hire the inspector yourself, reliance on this report may provide incomplete or outdated information. Repairs, professional opinions or additional inspection reports may affect the meaning of the information in this report.
Standards of Practice: NAHI National Association of Home Inspectors | In Attendance: Customer and their agent | Type of building: Single Family (2 story) |
Approximate age of building: Under 10 Years | Temperature: Below 65 | Weather: Cloudy |
Ground/Soil surface condition: Damp | Rain in last 3 days: Yes | Radon Test: No |
Water Test: No | Rough size of home (SQ FT): 3600 |
Roof Covering: 3-Tab fiberglass | Viewed roof covering from: Ladder Walked roof | Sky Light(s): None |
Chimney (exterior): N/A |
Inspection Items
|
| 1.0 | ROOF COVERINGS Comments: Repair or Replace | |
There is no drip edge installed on the outer edge of the wood sheathing. Although damage to the wood was not present at the time of the inspection, a roof without drip edge installed on it can cause premature rot to the sheathing. Recommend installing drip edge on the roof sheathing to extend the life of it. |
| 1.1 | FLASHINGS Comments: Inspected |
| 1.2 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS Comments: Repair or Replace | |
The plumbing vent pipe boot is raised up by what appears to be high winds. You will want to correct this issue to prevent water from entering around the boot and leaking into the attic. |
| 1.3 | ROOF DRAINAGE SYSTEMS (Gutters & Downspouts) Comments: Repair or Replace | |
The downspout in the right rear side of the home is missing a splashblock. You will want to install a properly angled splashblock to channel water away from the foundation. This is to keep water from building up along the foundation causing problems such as a leaking basement. |
Siding Style: Lap | Siding Material: Vinyl Brick veneer | Exterior Entry Doors: Wood |
Appurtenance: Deck with steps Porch | Driveway: Concrete |
Inspection Items
|
| 2.0 | WALL CLADDING FLASHING AND TRIM Comments: Repair or Replace | |
The vinyl siding on the upper left portion of the home has a loose piece that needs to be re-attached. |
| 2.1 | DOORS (Exterior) Comments: Repair or Replace | |
The front door sidelights have a small amount of soft wood at the bottom of the jam. Proper repairs can be made now to resolve this issue and halt the need for future door jam replacement. |
| 2.2 | WINDOWS Comments: Repair or Replace | |||
The rear windows casing and trim of the home around the deck have deteriorated. There are several "soft" spots in the trim that need to be replaced. Recommend having a qualified contractor make repairs as necessary. Note: You may find more damaged wood while repairs are being done. |
| 2.3 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES, PATIO/ COVER AND APPLICABLE RAILINGS Comments: Inspected |
| 2.4 | VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIO FLOOR, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building) Comments: Inspected |
| 2.5 | EAVES, SOFFITS AND FASCIAS Comments: Repair or Replace | |||
The soffit on the front right corner of the home has deteriorated wood that needs to be replaced. The gutter board, fascia, and rafter tips all show signs of water damage. It appears the lack of drip edge allowed water to get behind the gutter board and pool inside the soffit box. Over time this will cause the soffit to rot from the inside out. Care must be taken when making the repairs to remove all rotten wood to ensure the rot will not spread. |
Garage Door Type: Two automatic | Garage Door Material: Metal | Auto-opener Manufacturer: CHAMBERLAIN |
Inspection Items
|
| 3.0 | GARAGE CEILINGS Comments: Inspected |
| 3.1 | GARAGE WALLS (INCLUDING FIREWALL SEPARATION) Comments: Inspected |
| 3.2 | GARAGE FLOOR Comments: Inspected |
| 3.3 | GARAGE DOOR (S) Comments: Inspected |
| 3.4 | OCCUPANT DOOR FROM GARAGE TO INSIDE HOME Comments: Inspected |
| 3.5 | GARAGE DOOR OPERATORS Comments: Inspected |
Ceiling Materials: Drywall | Wall Material: Drywall | Floor Covering(s): Carpet Hardwood T&G Tile |
Interior Doors: Hollow core | Window Types: Double-hung | Cabinetry: Wood |
Countertop: Granite |
Inspection Items
|
| 4.0 | CEILINGS Comments: Inspected |
| 4.1 | WALLS Comments: Inspected |
| 4.2 | FLOORS Comments: Inspected |
| 4.3 | STEPS, STAIRWAYS, BALCONIES AND RAILINGS Comments: Inspected |
| 4.4 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS Comments: Inspected |
| 4.5 | DOORS (REPRESENTATIVE NUMBER) Comments: Inspected |
| 4.6 | WINDOWS (REPRESENTATIVE NUMBER) Comments: Inspected |
Method used to observe Crawlspace: No crawlspace | Foundation: Poured concrete | Floor Structure: Engineered floor trusses |
Wall Structure: 2 X 4 Wood | Columns or Piers: Steel screw jacks | Ceiling Structure: 2X8 |
Roof Structure: 2 X 8 Rafters | Roof-Type: Gable | Method used to observe attic: Walked |
Attic info: Pull Down stairs |
Inspection Items
|
| 5.0 | FOUNDATIONS, BASEMENTS AND CRAWLSPACES (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) Comments: Inspected |
| 5.1 | WALLS (Structural) Comments: Inspected |
| 5.2 | COLUMNS OR PIERS Comments: Inspected |
| 5.3 | FLOORS (Structural) Comments: Repair or Replace | |||
The half bath toilet is leaking and has caused damage to the plywood substrate beneath it. Repairs will need to be made to ensure spread of the rotten wood is eliminated. Recommend having a qualified contractor remove the toilet, make all necessary repairs to hardwood floor, plywood, and floor joist. Reset toilet with a new wax ring. |
| 5.4 | CEILINGS (structural) Comments: Inspected |
| 5.5 | ROOF STRUCTURE AND ATTIC Comments: Inspected |
Water Source: Public | Water Filters: None | Plumbing Water Supply (into home): Copper |
Plumbing Water Distribution (inside home): Copper | Plumbing Waste: PVC | Water Heater Power Source: Gas (quick recovery) |
Water Heater Capacity: 50 Gallon (2-3 people) | Manufacturer: BRADFORD-WHITE | Water Heater Location: Basement |
Water Heater Age: Under 10 Years |
Inspection Items
|
| 6.0 | PLUMBING DRAIN, WASTE AND VENT SYSTEMS Comments: Inspected |
| 6.1 | PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES Comments: Inspected |
| 6.2 | HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS Comments: Repair or Replace | |
The water heater has an insulation blanket installed which may void it's warranty. I recommend removing the blanket and checking with the manufacture to see if this is the case. |
| 6.3 | MAIN WATER SHUT-OFF DEVICE (Describe location) Comments: Inspected |
The main shut off is the red lever located on the front wall of the basement. This is for your information. |
| 6.4 | MAIN FUEL SHUT OFF (Describe Location) Comments: Inspected |
The main fuel shut off is at gas meter outside |
| 6.5 | SUMP PUMP Comments: Inspected |
| 6.6 | TOILETS Comments: Repair or Replace |
The hallway half bath toilet is leaking. Please see #5 Structural Components for further remarks. |
| 6.7 | SINKS Comments: Inspected |
| 6.8 | SHOWER STALLS Comments: Inspected |
Electrical Service Conductors: Below ground | Panel capacity: 200 AMP | Panel Type: Circuit breakers |
Electric Panel Manufacturer: SQUARE D | Branch wire 15 and 20 AMP: Copper | Wiring Methods: Romex |
Inspection Items
|
| 7.0 | SERVICE ENTRANCE CONDUCTORS Comments: Not Present |
| 7.1 | SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS Comments: Inspected |
| 7.2 | BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE Comments: Inspected |
| 7.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) Comments: Repair or Replace | |
The outlet in the upstairs bathroom is loose in the box. This is more than likely caused by repeated use. It may be necessary to replace the outlet all together if tightening the screws does not solve the problem. |
| 7.4 | POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE Comments: Inspected |
| 7.5 | OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS) Comments: Inspected |
| 7.6 | LOCATION OF MAIN AND DISTRIBUTION PANELS Comments: Inspected |
The main panel box is located at the basement. |
| 7.7 | SMOKE DETECTORS Comments: Safety |
| In accordance with home inspection industry standards, we do not test smoke detectors. However, they are an important safety feature that must not be overlooked, and it is important to make sure that there are functional detectors installed at all required locations prior to occupying the premises. |
| 7.8 | CARBON MONOXIDE DETECTORS Comments: Safety |
| Because it is not unusual for a lengthy period of time to pass between the time the inspection took place and when the home is actually occupied, it is imperative that all carbon monoxide detectors, both battery and hardwired, be tested for safe and proper function prior to occupation of the premises. |
Heat Type: Forced Air | Energy Source: Gas | Number of Heat Systems (excluding wood): One |
Heat System Brand: CARRIER | Ductwork: Insulated Non-insulated | Filter Type: Disposable |
Filter Size: 22x22 | Types of Fireplaces: Vented gas logs | Operable Fireplaces: One |
Number of Woodstoves: None | Cooling Equipment Type: Air conditioner unit | Cooling Equipment Energy Source: Electricity |
Central Air Manufacturer: CARRIER | Number of AC Only Units: One |
Inspection Items
|
| 8.0 | HEATING EQUIPMENT Comments: Inspected |
| 8.1 | NORMAL OPERATING CONTROLS Comments: Inspected |
| 8.2 | DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) Comments: Inspected |
| 8.3 | PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM Comments: Inspected |
| 8.4 | CHIMNEYS, FLUES AND VENTS (for fireplaces, gas water heaters or heat systems) Comments: Inspected |
| 8.5 | GAS/LP FIRELOGS AND FIREPLACES Comments: Inspected |
| 8.6 | COOLING AND AIR HANDLER EQUIPMENT Comments: Repair or Replace | |
The A/C was not tested for proper operation due to the outside air temperature is 65 degrees or less. We did not inspect this unit(s). The condensate line appears to be leaking or has leaked in the past. There is a green patina stain near the PVC condensate line. It is unclear if the unit is still leaking or not. I was not able to turn on the A/C due to a low outdoor temperature. You will want to have this issue checked once the temperature outside has reached a constant level of 65 degrees or higher. Repair as necessary.
| ||
The insulation around the large suction line is deteriorated. You may want to have the insulation repaired/replaced to improve the efficiency of the A/C unit. |
| 8.7 | NORMAL OPERATING CONTROLS Comments: Not Inspected |
| 8.8 | PRESENCE OF INSTALLED COOLING SOURCE IN EACH ROOM Comments: Inspected |
Attic Insulation: Blown | Ventilation: Soffit Vents Passive | Exhaust Fans: None |
Dryer Power Source: 220 Electric | Dryer Vent: Unknown | Floor System Insulation: NONE |
Inspection Items
|
| 9.0 | INSULATION IN ATTIC Comments: Inspected |
| 9.1 | INSULATION UNDER FLOOR SYSTEM Comments: Not Present |
| 9.2 | VAPOR RETARDERS (ON GROUND IN CRAWLSPACE OR BASEMENT) Comments: Not Present |
| 9.3 | VENTILATION OF ATTIC AND FOUNDATION AREAS Comments: Inspected |
| 9.4 | VENTING SYSTEMS (Kitchens, baths and laundry) Comments: Inspected |
| 9.5 | VENTILATION FANS AND THERMOSTATIC CONTROLS (ATTIC) Comments: Not Present |
Dishwasher Brand: GENERAL ELECTRIC | Disposer Brand: GENERAL ELECTRIC | Exhaust/Range hood: GENERAL ELECTRIC |
Range/Oven: GENERAL ELECTRIC | Built in Microwave: GENERAL ELECTRIC | Trash Compactors: NONE |
Refrigerator: GENERAL ELECTRIC |
Inspection Items
|
| 10.0 | DISHWASHER Comments: Inspected |
| 10.1 | RANGES/OVENS/COOKTOPS Comments: Inspected |
| 10.2 | RANGE HOOD Comments: Inspected |
| 10.3 | TRASH COMPACTOR Comments: Not Present |
| 10.4 | FOOD WASTE DISPOSER Comments: Inspected |
| 10.5 | MICROWAVE COOKING EQUIPMENT Comments: Inspected |

6407 Bardstown Rd. Suite 113
Louisville, KY 40291
502.938.5190
Customer
Mr. Joe Smith
Address
123 Dream Home Blvd
Louisville KY 40241
| 1. Roofing | |||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
| 2. Exterior | ||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||
| 5. Structural Components | ||||||||||||
|
||||||||||||
| 6. Plumbing System | |||||||||||||||||||
|
|||||||||||||||||||
| 7. Electrical System | ||||||||||
|
||||||||||
| 8. Heating / Central Air Conditioning | ||||||||||
|
||||||||||
There is no drip edge installed on the outer edge of the wood sheathing. Although damage to the wood was not present at the time of the inspection, a roof without drip edge installed on it can cause premature rot to the sheathing. Recommend installing drip edge on the roof sheathing to extend the life of it.